the application of ceramic stove cover and loading distance to the performance of water boiling system

Clicks: 86
ID: 144880
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #336 of 435 articles by views in acta botânica brasílica

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 435 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Conventional gas stove (CGS) used in the water boiling system (WBS) is quite inefficient if the mechanism is not considered. In the present research, an assessment has been performed to a CGS by applying a ceramic stove cover (CSC) and also investigated the optimum distance between CSC and the loading to obtain very best efficiency of a CGS. Several parameters used to investigate the CGS’s performance such as water temperature, heating value of the fuel and temperature of CSC have been used in reference to the definition of efficiency. In this study the distance between CSC and the loading is varied by 1 mm to 7 mm by increment of 1 mm. The results show that at a distance of 4 mm, the performance of a CGS in a certain fuel rate of 12.5 cc/s increase significantly indicated by the best efficiency of 46.4 %. It is because of an optimum condition is accomplished simultaneously in heat transfer processes such convection and radiation in the WBS. Although the fuel rate itself have an influence to the flame structure heating the loading, however, the used of ceramic cover have an effect to the exchange between fresh air and flue gas to the combustion process.
Reference Key
sugeng2018matecthe Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Widodo Agung Sugeng
Journal acta botânica brasílica
Year 2018
DOI
10.1051/matecconf/201815401109
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.