clinical validation results of an innovative non-invasive device for colorectal cancer preventive screening through fecal exhalation analysis

Clicks: 372
ID: 143731
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #22 of 132 articles by views in The Journal of investigative dermatology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 132 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Screening is recommended to reduce both incidence and mortality of colorectal cancer. Currently, many countries employ fecal occult blood test (FOBT). In Emilia-Romagna (Italy), since 2005, FOBT immunochemical version (FIT) is performed every two years on people aged between 50 and 69 years. A colonoscopy is then carried out on those who are FIT positive. However, FIT shows approximately 65% false positives (non-tumoral bleedings), leading to many negative colonoscopies. The use of an economic and easy-to-use method to check FOBT-positives will improve screening effectiveness, reducing costs to the national health service. This work illustrates the results of a three-year clinical validation protocol (started in 2016) of a patented device composed of a core of nanostructured gas sensors. This device was designed to identify CRC presence by fecal volatile compounds, with a non-invasive, in vitro and low-cost analysis. Feces are, in fact, affected by tumor-volatile biomarkers, produced by cellular peroxidation and metabolic alterations. The protocol consisted in the analysis of fecal samples of FIT-positive subjects, using colonoscopy as a gold standard. A total of 398 samples were analyzed with machine learning techniques, leading to a sensitivity and specificity of 84.1% and 82.4%, respectively, and a positive predictive value of 72% (25–35% for FIT).
Reference Key
zonta2020cancersclinical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal The Journal of investigative dermatology
Year 2020
DOI
10.3390/cancers12061471
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.