volume capnography: a narrative review
Clicks: 148
ID: 143478
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
148 views
39 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #12 of 17 articles by views in Minerva anestesiologica
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Volume capnography is the graph of expired carbon dioxide concentration against the expired volume. It often requires special and bulky equipment to be recorded. It can be used to estimate the dead space with fair amount of precision. Various formulae and equations have been described to estimate the dead space. While the Bohr formula is likely the most accurate for measurement of dead space, the Enghoff's equation is likely the most popular and convenient to use. Volume capnography has found uses in both the operating room (OR) and the Intensive Care Unit setting. It can be used to identify the optimal level of positive end-expiratory pressure in patients suffering from the acute respiratory distress syndrome as well as to identify its effect on the ventilation. In the OR, it can be invaluable to monitor ventilation and alveolar recruitment in the obese population. It is also a useful diagnostic adjunct in medical emergencies like pulmonary embolism. In the pediatric population, it finds uses in the monitoring of infants suffering from bronchiolitis. In spite of its multiple and diverse uses, it remains an underutilized technology; the main reasons for this being lack of experience of the providers with volume capnography and the expensive and bulky equipment that is often required. However, volume capnography has a great deal of potential and with further advances in technology, is likely to gain popularity.
| Reference Key |
singh2017thevolume
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Shubhangi Singh;Bhavani Shankar Kodali |
| Journal | Minerva anestesiologica |
| Year | 2017 |
| DOI |
10.4103/TheIAForum.TheIAForum_27_17
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.