plastia da valva mitral com a técnica do "duplo teflon": resultados de 10 anos mitral valve repair with "double teflon" technique: 10-year results
Article Quality & Performance Metrics
Readership in this journal
SteadyRanked #57 of 103 articles by views in 2017 international conference on information technology systems and innovation, icitsi 2017 - proceedings
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
OBJECTIVE: The purpose of this paper is to present the late clinical results of mitral valve repair with the "Double Teflon" technique. METHODS: "Double Teflon" technique consists of a quadrangular resection of the posterior leaflet, annulus plication with "pledgetted" stitches over a Teflon patch, and leaflet suture. Between 1994 and 2003, 133 patients with degenerative mitral insufficiency due to ruptured or elongated chordae in the posterior leaflet underwent repair with this technique. The mean patient age was 60.4 years and 60.9% patients were male. According to clinical evaluation, 29.3% of the patients were in New York Heart Association functional class IV, 55.7% in class III and 15.0% in class II. Associated techniques of mitral valve repair were used in 15.2% of the patients; the most common was chordal shortening. Twenty six (19.5%) patients had associated procedures. RESULTS: There was one (0.75%) operative death. In the late postoperative period, 95.5% of the surviving patients were in New York Heart Association functional class I. Linearized rates of thromboembolism, reoperation and death were 0.9%, 0.3% and 0.6% patient/year, respectively. The actuarial survival at 10 years was 94.7% ± 3.6%. Actuarial freedom from thromboembolism and reoperation were 97.3 ± 1.5% and 99.2 ±0.8%, respectively. There were no episodes of hemolysis or endocarditis. CONCLUSION: Mitral valve repair with "Double Teflon" technique presents low morbimorbidity and good clinical late evolution.
| Reference Key |
brando2007brazilianplastia
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Carlos Manuel de Almeida Brandão;Marco Antonio Vieira Guedes;Marcos Floripes da Silva;Marcelo Luiz Vieira;Pablo Maria Alberto Pomerantzeff;Noedir Antonio Groppo Stolf |
| Journal | 2017 international conference on information technology systems and innovation, icitsi 2017 - proceedings |
| Year | 2007 |
| DOI |
10.1590/S0102-76382007000400011
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.