optimization of 3d planning dosimetry in a breast phantom for the match region of supraclavicular and tangential fields

Clicks: 241
ID: 142419
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #46 of 81 articles by views in the international archives of the photogrammetry, remote sensing and spatial information sciences

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and tangential fields, utilizing Gafchromic EBT film for dosimetry. Material and Methods: In this study, a slab phantom was designed with lung- and heart-equivalent inhomogetenities. Our measurements were carried out using Gafchromic EBT film. Irradiations were performed using the 6 MV photon beam of a Varian 2100 Clinac linear accelerator. Three-dimensional treatment planning and dose calculations were carried out using the RT Dose Plan software. The conventional method with source-to-skin distance match and a 3D method with source-to-axis distance match under different combinations of parameters such as gantry, collimator and couch rotations as well as asymmetric fields were utilized. Results: The results demonstrated differences between the 3D and conventional techniques. The best results in the match region were observed using the 3D method with asymmetric technique (maximum area of overlap = 0.43 cm2, depth of overlap = 3.55 cm, and average width of overlap = 0.75 cm). Discussion and Conclusion: This study shows that the EBT film is a suitable tool for two-dimensional distribution dosimetry and relative dose measurements. The study shows difficulties in achieving a homogenous dose distribution in the match region of supraclavicular and tangential fields and also demonstrates the effects of setup parameters on matching of treatment fields.
Reference Key
nourollahi2011iranianoptimization Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Somayeh Nourollahi;Mahmoud Allahverdi;Mahbod Esfahani;Mehdi Aghili;Vahid Changizi
Journal the international archives of the photogrammetry, remote sensing and spatial information sciences
Year 2011
DOI
10.22038/ijmp.2011.7231
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.