a comparative scanning electron microscopic analysis of the effect of qmix® and sofscale™ as an adjunct to scaling and root planing on periodontally compromised root surfaces: an in vitro study
Clicks: 267
ID: 140749
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
267 views
45 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #25 of 68 articles by views in biomedical sciences instrumentation
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Aim: This study aimed to comparatively analyze, under scanning electron microscope (SEM), the effect of the use of QMix® and SofScale™ as an adjunct to scaling and root planing (SRP) on periodontally compromised root surfaces. Settings and Design: This study was carried out in K. M. Shah Dental College and Hospital, Vadodara. Methodology: This was a single-blinded in vitro study which compared QMix® and SofScale™ as an adjunct to SRP on periodontally compromised root surfaces under SEM. Statistical Analysis Used: Statistical analysis was done using a nonparametric Mann–Whitney U-test to test the null hypothesis that there is no difference between the test and control groups. Results: The sum of ranks for QMix® was 306.50 and the sum of ranks for SofScale™ was 513.50. The group which was treated with QMix® showed statistically significant results (P = 0.004) as compared to group which was treated with SofScale™.Conclusion: Comparative analysis showed that QMix® had significantly better smear layer removal ability as compared to SofScale™. However, uniform root surface was achieved with both QMix® and SofScale™.
| Reference Key |
nawathe2017contemporarya
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Abhay A Nawathe;Neeraj C Deshpande;Shivani A Dandekar |
| Journal | biomedical sciences instrumentation |
| Year | 2017 |
| DOI |
10.4103/ccd.ccd_539_17
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.