analysis of acid pitchstone (iceland) using laser induced breakdown spectroscopy (libs)
Clicks: 222
ID: 140403
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
222 views
23 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #41 of 91 articles by views in comparative biochemistry and physiology toxicology & pharmacology : cbp
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Analysis of acid pitchstone (sample from Iceland) using laser induced breakdown spectroscopy (LIBS) is presented in this study. The rock sample was taken because of its uniform composition and a homogenous structure at microscale. Elements like Si, Fe, Ca, Mg, Al, Mn, Ti, Na, K, Ba, Sr and Li were detected in the LIBS spectra. Important plasma parameters (electron density and temperature) were calculated on the base of Stark broadening mechanism of spectral lines and Saha- Boltzmann plot method, respectively. Quantitative analysis was performed using calibration free (CF) approach of LIBS method. CF-LIBS analysis compared to reconstructed bulk rock analysis using precise mineral and glass analyses obtained by electron microprobe analysis (EMPA) gives a good correlation, sufficient enough for having primary information of chemical composition of the studied rock sample or alternatively large mineral phases. An element with very low atomic number, lithium, was detected only by LIBS. Li is not detectable on microprobe. Taking into account possible local mineral accumulations and imprecisions induced by estimation of mineral volumes in the glass the CF-LIBS method gives acceptably precise analyses for geological purposes.
| Reference Key |
veis2013actaanalysis
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Pavel Veis;Ivan Holický;Patrik Konečný;Jakub Hulík;Jozef Plavčan;Zuzana Grolmusová;Michaela Horňáčková |
| Journal | comparative biochemistry and physiology toxicology & pharmacology : cbp |
| Year | 2013 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations