analysis of acid pitchstone (iceland) using laser induced breakdown spectroscopy (libs)

Clicks: 222
ID: 140403
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #41 of 91 articles by views in comparative biochemistry and physiology toxicology & pharmacology : cbp

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Analysis of acid pitchstone (sample from Iceland) using laser induced breakdown spectroscopy (LIBS) is presented in this study. The rock sample was taken because of its uniform composition and a homogenous structure at microscale. Elements like Si, Fe, Ca, Mg, Al, Mn, Ti, Na, K, Ba, Sr and Li were detected in the LIBS spectra. Important plasma parameters (electron density and temperature) were calculated on the base of Stark broadening mechanism of spectral lines and Saha- Boltzmann plot method, respectively. Quantitative analysis was performed using calibration free (CF) approach of LIBS method. CF-LIBS analysis compared to reconstructed bulk rock analysis using precise mineral and glass analyses obtained by electron microprobe analysis (EMPA) gives a good correlation, sufficient enough for having primary information of chemical composition of the studied rock sample or alternatively large mineral phases. An element with very low atomic number, lithium, was detected only by LIBS. Li is not detectable on microprobe. Taking into account possible local mineral accumulations and imprecisions induced by estimation of mineral volumes in the glass the CF-LIBS method gives acceptably precise analyses for geological purposes.
Reference Key
veis2013actaanalysis Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Pavel Veis;Ivan Holický;Patrik Konečný;Jakub Hulík;Jozef Plavčan;Zuzana Grolmusová;Michaela Horňáčková
Journal comparative biochemistry and physiology toxicology & pharmacology : cbp
Year 2013
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.