emission rate variation and efficiency measurement in tio2 light emitting diode
Clicks: 163
ID: 138934
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
163 views
36 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #156 of 435 articles by views in acta botânica brasílica
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 435 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Titanium dioxide light emitting diode was successfully designed and characterised. An approach in developing TiO2 was based on cylindrically symmetric configuration with shorter computation time. The main goal of the research was to look into the performance of light emitting diode by using titanium dioxide and compare its validity with the standard or common criteria. The circular chip of titanium dioxide with 60 μm diameters was made with a circular active region formed by p and ntype dopants. The drastic reduction of internal quantum efficiency droops almost to zero value even though the current started to increase by 0.002 mA. The efficient operation within the device was observed that it would occur at the lowest current 0.01 mA while the total emission rate shown linearly increased at axis (0.002 mA, 5.6 (1/s)). This light emitting diode based on titanium dioxide also enabled to operate at lower turn-on voltage as low as 0.5 V. As the increment of voltages, the distribution of emission rate became less concentrated towards the top active of p-type layer of the device. The result also compared the two meshes where it was found that the refined mesh was focused around the p-n junction.
| Reference Key |
s.n.2016matecemission
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Ariffin S.N.;Hambali N.A.M.A.;Wahid M.H.A.;Shahimin M.M.;Sahbudin U.K.;Saidi N.N.A. |
| Journal | acta botânica brasílica |
| Year | 2016 |
| DOI |
10.1051/matecconf/20167801111
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.