fatores envolvidos na migração das endopróteses em pacientes submetidos ao tratamento endovascular do aneurisma da aorta abdominal factors involved in the migration of endoprosthesis in patients undergoing endovascular aneurysm repair
Article Quality & Performance Metrics
Readership in this journal
SteadyRanked #6 of 41 articles by views in medecine et sante tropicales
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
Migration of the endoprosthesis is defined as the misplacement of its initial fixation. To assess the migration, the position of the endoprosthesis regarding a certain anatomic region is verified. Considering the aneurysm of the infrarenal abdominal aorta, the proximal area of reference is the origin of the lowest renal artery and, at the distal region, it is located next to the internal iliac arteries. Patients should be monitored for long periods so that migrations can be identified; these migrations usually occur 2 years after the implantation. To avoid migrations, mechanical forces that enable fixation and that are determined by the characteristics of the devices and by the incorporation of the endoprosthesis should predominate over gravitational and hemodynamic forces, which tend to drag the prosthesis toward to caudal direction. Angulation, extension, and diameter of the neck, and transversal measure of the aneurysmatic sac are important morphological aspects related to migration. In relation to the technique, endoprosthesis implantation with excessive oversizing (> 30%) is not recommended because it leads to aortic neck dilatation, folds and proximal leakage that also contribute to migration. On the other hand, endoprosthesis with additional fixation devices (hooks, barbs and suprarenal fixation) seem to be less associated with migration. The process of endoprosthesis incorporation is partial and does not seem to be enough to prevent later migrations. In this sense, experimental studies with endoprosthesis of higher porosity, as well as the use of substances that allow higher fibroplasia and adherence of the prosthesis to the artery, have been conducted and are promising. Such aspects are discussed in the present review of the literature.
| Reference Key |
almeida2010jornalfatores
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Marcelo José de Almeida;Winston Bonetti Yoshida;Ludvig Hafner;Juliana Henrique dos Santos;Bruno Felipe Souza;Flávia Fagundes Bueno;Janaína Lopes Evangelista;Lucas José Vaz Schiavão |
| Journal | medecine et sante tropicales |
| Year | 2010 |
| DOI |
10.1590/S1677-54492010000200009
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.