lateral coolant flow between fuel assemblies in mixed cores
Clicks: 101
ID: 138244
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
101 views
7 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #108 of 829 articles by views in BMC Bioinformatics
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 829 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This paper presents the results of an analysis of lateral coolant flow between adjacent fuel assemblies with non-identical spacing grids in a mixed core consisting of TVSA-T mod.1 and TVSA-T mod.2 fuel assemblies. The calculation was carried out using modified subchannel code SUBCAL which allows to calculate 3D thermo-hydraulic characteristics of the coolant flow in the full three fuel assemblies model. This full three fuel assemblies model was created in two variants. The first variant consisted of three hydraulically identical fuel assemblies TVSA-T mod.1, whereas the second variant consisted of two fuel assemblies TVSA-T mod.1 and one fuel assembly TVSA-T mod.2 which mainly differ in types, number and axial coordinate of spacing grids and also in diameter of guide tubes. The influence of mixed core to lateral coolant flow and hence coolant temperature was obtained by comparing these two variants. The power distribution was taken from presumed mixed core fuel reload calculated by macro-code ANDREA. Finally there were also provided a comparison of results achieved by subchannel analysis approach with calculation of similar problem using CFD code ANSYS CFX by TVEL, the fuel supplier.
| Reference Key |
caha2018actalateral
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Vojtech Caha;Jiří Čížek |
| Journal | BMC Bioinformatics |
| Year | 2018 |
| DOI |
10.14311/APP.2018.14.0001
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.