avaliação do pool de plasma caseiro como controle normal para o tempo de tromboplastina parcial ativada (ttp) evaluation if in-house preparations of polled plasma can be used as a normal control of partial thromboplastin time (ptt)
Article Quality & Performance Metrics
Readership in this journal
SteadyRanked #39 of 53 articles by views in industrial and engineering chemistry research
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
INTRODUCTION: Proper utilization of plasma control for comparison with the plasma of patients with coagulation tests is critical to ensure a safe outcome of these laboratory tests. OBJECTIVE: The purpose of this work was to know if in-house preparations of polled plasma can be used as a normal control of partial thromboplastin time (PTT). MATERIAL AND METHOD: We make two polled plasma, one with five (P5) samples and another with 20 (P20) samples, both of them from normal patients. Both pooled plasma were analyzed in comparison with a commercial lyophilized control (AP). The experiment was performed in 10 days, and P5 and P20 were made daily. At each day PTT was performed for P5, P20 and AP. All patients who asked for TTP, in each day of this experience, got a time relation (R) determined by a P5, P20 e AP. Tukey test was used as statistical analysis. RESULTS: Statistically significant differences were detected among the PTT for AP and P5, AP and P20, but no difference between P5 and P20 was observed. When the time relations were tested, there were no significant difference, among AP, P5, and P20. CONCLUSION: We found that in-house preparations of polled plasma (P5 and P20) can be used as a normal control of PTT.
| Reference Key |
henneberg2011jornalavaliao
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | |
| Journal | industrial and engineering chemistry research |
| Year | 2011 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.