evaluation of the portal imaging system performance for an elekta precise linac in radiotherapy

Clicks: 275
ID: 137096
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #35 of 81 articles by views in the international archives of the photogrammetry, remote sensing and spatial information sciences

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Introduction: Electronic portal imaging devices (EPIDs) provide two- and three-dimensional planar and volumetric cone beam images to improve the accuracy of radiation treatment delivery. Periodic quality assurance (QA) of EPIDs is essential for dosimetric verification in radiotherapy. In this study, a QA program was implemented to evaluate the function of the EPID to be confident in applying corrections for the uncertainty of patient set-up. Material and Methods: Firstly, the safety features were verified, and the uniformity of EPID response was evaluated using flat panel detector. Additionally, the contrast and spatial resolutions of the EPID were assessed using detail counting of the Los Vegas phantom images by visualization method and measuring the modulation transfer function using edge technique, respectively. Moreover, a combination of smoothing methods was used for optimal use of edge detection algorithm for the noisy portal images. Finally, the location of the central ray on the EPID surface at different gantry angles was determined to evaluate the mechanical stability of the supporting arm. Results: The safety interlocks were found to be functional.The EPID response variation was less than 3% according to the results obtained from the detector. The contrast resolution met the recommended tolerance; however, the visualization method was widely observer-dependent. The value of f50 for spatial resolution was 0.401±0.005 lp/mm for the photon energy of 6 MV. The supporting arm deviation was within ±1 mm. Conclusion: The periodic QA of image guidance system gave confidence to apply the corrections for set-up in clinic.
Reference Key
shahedi2018iranianevaluation Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Fatemeh Shahedi;Mehdi Momennezhad;shahrokh Nasseri;Hamid Gholamhosseinian
Journal the international archives of the photogrammetry, remote sensing and spatial information sciences
Year 2018
DOI
10.22038/ijmp.2018.27401.1287
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.