dosimetric effects of the interfraction variations during whole breast radiotherapy: a prospective study.

Clicks: 305
ID: 134326
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #65 of 207 articles by views in international journal of heat and technology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 207 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Introduction: The aim of this work was to assess the dosimetric impact of the interfraction variations during breast radiotherapy.Material and methods: Daily portal imaging measurements were prospectively performed in 10 patients treated with adjuvant whole breast irradiation (50 Gy/25 fractions). Margins between the Clinical Target Volume (CTV) and the Planning Target Volume (PTV) were 5 mm in the three dimensions. Parameters of interest were the Central Lung Distance (CLD) and the Inferior Central Margin (ICM). Daily movements were applied to the baseline treatment planning (TP1) to design a further TP (TP2). The PTV coverage and organ at risk exposure were measured on both TP1 and TP2, before being compared.Results: A total of 241 portal images were analyzed. The random and systematic errors were 2.6 mm and 3.7 mm for the CLD, 4.3 mm and 6.9 mm for the ICM, respectively. No significant consequence on the PTV treatments was observed (mean variations: +0.1%, p=0.56, and -1.8%, p=0.08 for the breast and the tumor bed, respectively). The ipsilateral lung and heart exposure was not significantly modified.Conclusion: In our series, the daily interfraction variations had no significant effect on the PTV coverage or healthy tissue exposure during breast radiotherapy.
Reference Key
ejacob2015frontiersdosimetric Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Julian eJacob;Steve eHeymann;Isabelle eBorget;Isabelle eBorget;Isabelle eDumas;Elyes eRiahi;Pierre eMaroun;Patrick eEzra;Elena eRoberti;Sofia eRivera;Eric eDeutsch;Eric eDeutsch;Céline eBourgier;Céline eBourgier;Céline eBourgier
Journal international journal of heat and technology
Year 2015
DOI
10.3389/fonc.2015.00199
URL
Keywords