avaliação prospectiva do índice de líquido amniótico em gestações normais e complicadas prospective evaluation of amniotic fluid index in normal and high risk pregnancies
Clicks: 378
ID: 133812
2005
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
4.8
/100
16 views
16 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
OBJETIVO: Analisar, prospectivamente, o índice de líquido amniótico em gestantes de baixo risco que apresentaram ou não complicações da gestação e do período perinatal. MATERIAIS E MÉTODOS: Foi estudado, de modo prospectivo, o índice de líquido amniótico de 45 primigestas sem doenças no momento da inclusão no estudo. O índice foi avaliado em quatro períodos da gestação - 18-20, 24-26, 28-30 e 34-36 semanas - e seus valores foram correlacionados com o surgimento de complicações gestacionais e perinatais, Doppler das artérias uterinas, idade gestacional ao parto, vias de parto e o peso dos recém-nascidos. RESULTADOS: O índice de líquido amniótico não mostrou diferença estatística entre as pacientes com gestações normais e complicadas em nenhum dos quatro períodos estudados. Também não mostrou associação com a idade gestacional ao parto, as vias de parto e o peso dos recém-nascidos. Observou-se que a média do índice de líquido amniótico entre 28-30 semanas é mais elevada (p = 0,004) nas pacientes com incisura bilateral do que nas com Doppler normal. CONCLUSÃO: A avaliação prospectiva do índice de líquido amniótico em gestações de baixo risco parece não ser um bom preditor de complicações gestacionais ou perinatais.
OBJECTIVE: To prospectively analyze the amniotic fluid index of low-risk pregnant women who presented or not complications during pregnancy and perinatal period. MATERIALS AND METHODS: The amniotic fluid index was prospectively studied in 45 first pregnancy women with no diseases at study entry. The amniotic fluid index was determined at four time points during pregnancy - 18-20, 24-26, 28-30 and 34-36 weeks - and the values were correlated with the appearance of pregnancy and perinatal complications, uterine artery Doppler findings, gestational age at delivery, route of delivery, and newborn weight. RESULTS: Amniotic fluid index was not significantly different among patients with normal and high risk pregnancies at any of the four time points studied. Likewise, there was no association with gestational age at delivery, route of delivery or newborn weight. The mean amniotic fluid index at 28-30 weeks was higher (p = 0.004) in patients with bilateral incisure than in patients with normal Doppler. CONCLUSION: Prospective evaluation of amniotic fluid index in low-risk pregnancies does not seem to be a good predictor of complications during pregnancy or perinatal period.
OBJECTIVE: To prospectively analyze the amniotic fluid index of low-risk pregnant women who presented or not complications during pregnancy and perinatal period. MATERIALS AND METHODS: The amniotic fluid index was prospectively studied in 45 first pregnancy women with no diseases at study entry. The amniotic fluid index was determined at four time points during pregnancy - 18-20, 24-26, 28-30 and 34-36 weeks - and the values were correlated with the appearance of pregnancy and perinatal complications, uterine artery Doppler findings, gestational age at delivery, route of delivery, and newborn weight. RESULTS: Amniotic fluid index was not significantly different among patients with normal and high risk pregnancies at any of the four time points studied. Likewise, there was no association with gestational age at delivery, route of delivery or newborn weight. The mean amniotic fluid index at 28-30 weeks was higher (p = 0.004) in patients with bilateral incisure than in patients with normal Doppler. CONCLUSION: Prospective evaluation of amniotic fluid index in low-risk pregnancies does not seem to be a good predictor of complications during pregnancy or perinatal period.
| Reference Key |
costa2005radiologiaavaliao
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Fabrício da Silva Costa;Sérgio Pereira da Cunha;Aderson Tadeu Berezowski |
| Journal | india international conference on information processing, iicip 2016 - proceedings |
| Year | 2005 |
| DOI |
10.1590/S0100-39842005000500006
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.