determination of trace copper in water samples by flame atomic absorption spectrometry after preconcentration on a phosphoric acid functionalized cotton chelator
Clicks: 222
ID: 132205
2008
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
222 views
41 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #85 of 151 articles by views in meditsinskaia radiologiia
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 151 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This paper reports the preparation of a phosphorylated cotton chelator (PCC) by solid phase esterification of phosphoric acid (PA) onto defatted cotton fibres using urea as the catalyst. The synthesized PCC was employed for the preconcentration of copper from water samples prior to its determination by flame atomic absorption spectrometry (FAAS). The preconcentration of copper was studied under both batch and column techniques. The pH range for the quantitative preconcentration of copper was 4.0–7.0. The sorption time required for each sample was less than 30 min by the batch method. The copper sorption capacity of the PCC was found to be 15.3 mg/g at the optimum pH value. Elution with 1.0 mol dm-3 hydrochloric acid was found to be quantitative. Feasible flow rates of the copper solution for quantitative sorption onto the column packed with PCC were 0.5–4.0 ml min-1, whereas the optimum flow rate of the hydrochloric acid solution for desorption was less than 1.5 ml min-1. An 80-fold preconcentration factor could be achieved under the optimum column conditions. The tolerance limits for common metal ions on the preconcentration of copper and the number of times of column reuse were investigated. The proposed method was successfully applied for the preconcentration and determination of trace copper in natural and drinking water samples by FAAS.
| Reference Key |
liu2008journaldetermination
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;XINGYAN LIU;MIN FENG;KEDING ZHONG;DEMIN ZHANG;RENMIN GONG |
| Journal | meditsinskaia radiologiia |
| Year | 2008 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.