description of an evaluation system for knee kinematics in ligament lesions, by means of optical tracking and 3d tomography,
Clicks: 142
ID: 131416
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
142 views
22 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #54 of 69 articles by views in scientific american
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Objective:To describe and demonstrate the viability of a method for evaluating knee kine matics, by means of a continuous passive motion (CPM) machine, before and after anterio cruciate ligament (ACL) injury.Methods:This study was conducted on a knee from a cadaver, in a mechanical pivot-shif simulator, with evaluations using optical tracking, and also using computed tomography.Results:This study demonstrated the viability of a protocol for measuring the rotation an translation of the knee, using reproducible and objective tools (error<0.2mm). The mech anized provocation system of the pivot-shift test was independent of the examiner an always allowed the same angular velocity and traction of 20 N throughout the movement.Conclusion:The clinical relevance of this method lies in making inferences about the in viv behavior of a knee with an ACL injury and providing greater methodological quality in futur studies for measuring surgical techniques with grafts in relatively close positions.
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (82 words).
Try re-searching for a better abstract.
| Reference Key |
fernandes2014revistadescription
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Tiago Lazzaretti Fernandes;Douglas Badillo Ribeiro;Diogo Cristo da Rocha;Cyro Albuquerque;César Augusto Martins Pereira;André Pedrinelli;Arnaldo José Hernandez |
| Journal | scientific american |
| Year | 2014 |
| DOI |
10.1016/j.rboe.2014.08.005
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.