Determination of amphetamine-type stimulants in urine samples using microextraction by packed sorbent and gas chromatography-mass spectrometry.
Clicks: 294
ID: 1287
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
64.0
/100
294 views
239 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #18 of 46 articles by views in journal of chromatography b, analytical technologies in the biomedical and life sciences
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The aim of this work was the development, optimization and full validation of a method applying microextraction by packed sorbent (MEPS) coupled to gas chromatography-mass spectrometry (GC-MS) to determine amphetamine (AMP), methamphetamine (MAMP), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxyethylmethamphetamine (MDMA), 3,4-methylenedioxy-N-methyl-α-ethylfenilethylamine (MBDB), and 3,4-methylenedioxy-N-ethylamphetamine (MDE) in urine samples. Using 200 μL of sample, the MEPS procedure was optimized concerning type of sorbent, sample dilution, number of strokes, activation of the ion exchange mechanism and composition of both washing and elution solvents. The method was fully validated according to the Food and Drug Administration and the Scientific Working Group of Forensic Toxicology guidelines for the validation of bioanalytical methods. The studied parameters included selectivity, calibration model and linearity, limits of detection and quantification, precision, accuracy, stability, dilution integrity and recoveries. Linearity was obtained in the range of 25-1000 ng/mL for MAMP, MBDB and MDE, 35-1000 ng/mL for AMP and MDMA, and 50-1000 ng/mL for MDA, with coefficients of determination (R) >0.99 for all analytes. Both intra- and inter-day precision and accuracy were adequate, and coefficients of variation lower than 15% and mean relative errors (RE) within a range of ±15% of the theoretical concentrations were obtained for all compounds under study. Analyte recoveries ranged from 19 to 71%, allowing LLOQs ≤50 ng/mL.
| Reference Key |
malaca2019determination
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Malaca, Sara;Rosado, Tiago;Restolho, José;Rodilla, Jesus M;Rocha, Pedro M M;Silva, Lúcia;Margalho, Cláudia;Barroso, Mário;Gallardo, Eugenia; |
| Journal | journal of chromatography b, analytical technologies in the biomedical and life sciences |
| Year | 2019 |
| DOI |
S1570-0232(19)30010-8
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.