Colorimetric aflatoxins immunoassay by using silica nanoparticles decorated with gold nanoparticles.

Clicks: 443
ID: 128071
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #13 of 116 articles by views in spectrochimica acta part a, molecular and biomolecular spectroscopy

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Nanomaterials-based colorimetric immunoassays showed increasing attention for monitoring different biomarkers because of their unique optical and electrical features. Here, a highly sensitive and selective optical sensor was described for the determination of different aflatoxins (AFs). Mesoporous silica nanoparticles (m-SNPs) with an average particle size of 40 nm were prepared by the sol-gel method and then decorated with gold nanoparticles (AuNPs). The Au NPs@m-SiNPs nanocomposite with an average particle size of 66 nm was modified with AFs antibodies. The assay includes the following steps: the Au NPs@m-SiNPs nanocomposite was immersed with AFs antibodies, and then the AFs-Ab/Au NPs@m-SiNPs was used as a probe for AFs detection. The interaction between the AFs-Ab/Au NPs@m-SiNPs and the AFs has resulted in a change in its color from pink to violet. Measurements are performed by absorptiometry at a wavelength of 425 nm. The immunoassay works in the concentration range from 1 ng·mL to 75 ng·mL AFB1 and has a limit of detection 0.16 ng·mL (at S/N = 3). The assay was applied to the determination of AFs in different food samples spiked with AFS. Finally, the assay was used to detect AFs in a real sample, and the LC-MS technique was used to verify the results.
Reference Key
althagafi2020colorimetricspectrochimica Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal spectrochimica acta part a, molecular and biomolecular spectroscopy
Year 2020
DOI
S1386-1425(20)30978-1
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.