A Drinking Water Relevant Water Chemistry Model for the Free Chlorine and Cyanuric Acid System from 5 to 35 °C.

Clicks: 349
ID: 1182
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #2 of 11 articles by views in environmental engineering science

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
In the United States, approved methods to measure free chlorine concentrations in drinking water systems adding sodium dichloroisocyanurate (dichlor) or trichloroisocyanuric acid (trichlor) as chlorine sources exhibit measurement bias from chlorinated cyanurate presence, leading to overestimated free chlorine concentrations for regulatory compliance. One option to overcome this limitation is to estimate free chlorine concentrations using an established water chemistry model (full model), but the full model has only been determined for 25 °C. The current research used a simplified version of the full model (simple model) and estimated the unknown temperature dependence (5 to 35 °C) of the two remaining equilibrium constants (K and K) required for the simple model. At 0 M ionic strength (μ), ln K 7a = - 4 , 671 T K + 4.95 or pK 7a = 2 , 028 T K - 2.15 , Δ H 7a 0 = 38.8 ± 6.0 kJ mol (95% confidence interval, CI), ln K 9a = - 5 , 133 T K + 3.79 or pK 9a = 2 , 229 T K - 1.65 , and Δ H 9a 0 = 42.7 ± 3.0 kJ mol (95% CI). At 25 °C and μ of 0 M, the simple model estimated pK and pK are 4.65 ± 0.059 (95% CI) and 5.83 ± 0.020 (95% CI), respectively. As an example of temperature's impact, the free chlorine concentration for a 2 mg Cl L dichlor addition (pH 7.0) decreases from 0.90 mg Cl L free chlorine at 25 °C to 0.60 mg Cl L free chlorine at 5 °C. If temperature was not considered, a system operating at 5 °C would overestimate their free chlorine concentration by 50%, which could have significant implications for understanding disinfection efficacy, illustrating the developed model's significance.
Reference Key
wahman2019a Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Wahman, David G;Alexander, Matthew T;
Journal environmental engineering science
Year 2019
DOI
10.1089/ees.2018.0387
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.