New solar axion search using the CERN Axion Solar Telescope with He4 filling

Clicks: 104
ID: 114781
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #135 of 151 articles by views in physical review d

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 151 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The CERN Axion Solar Telescope (CAST) searches for $a\ensuremath{\rightarrow}\ensuremath{\gamma}$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. Two parallel magnet bores can be filled with helium of adjustable pressure to match the x-ray refractive mass ${m}_{\ensuremath{\gamma}}$ to the axion search mass ${m}_{a}$. After the vacuum phase (2003--2004), which is optimal for ${m}_{a}\ensuremath{\lesssim}0.02\text{ }\text{ }\mathrm{eV}$, we used $^{4}\mathrm{He}$ in 2005--2007 to cover the mass range of 0.02--0.39 eV and $^{3}\mathrm{He}$ in 2009--2011 to scan from 0.39 to 1.17 eV. After improving the detectors and shielding, we returned to $^{4}\mathrm{He}$ in 2012 to investigate a narrow ${m}_{a}$ range around 0.2 eV (``candidate setting'' of our earlier search) and 0.39--0.42 eV, the upper axion mass range reachable with $^{4}\mathrm{He}$, to ``cross the axion line'' for the KSVZ model. We have improved the limit on the axion-photon coupling to ${g}_{a\ensuremath{\gamma}}<1.47\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}\text{ }\text{ }{\mathrm{GeV}}^{\ensuremath{-}1}$ (95% C.L.), depending on the pressure settings. Since 2013, we have returned to the vacuum and aim for a significant increase in sensitivity.
Reference Key
2015physicalnew Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal physical review d
Year 2015
DOI
doi:10.1103/PhysRevD.92.021101
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.