The “No ARSA” Sign: A Novel Method of Prenatal Screening for Aberrant Right Subclavian Artery
Clicks: 234
ID: 114600
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
234 views
49 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #195 of 253 articles by views in journal of clinical medicine
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 253 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
An aberrant right subclavian artery (ARSA) can be overlooked by the conventional method as described by Chaoui et al., due to acoustic shadowing. The aim of this study was to evaluate the feasibility and accuracy of a novel screening method for ARSA by demonstrating the brachiocephalic artery bifurcation, referred to as the “No ARSA” sign. A prospective study conducted at a tertiary care center between 2018 and 2019 included unselected pregnant patients at a median gestational age of 15.1 (14.2–22.1; IQR (inter-quartile range)) weeks, who had been referred for a routine or targeted anomaly scan. All participants were scanned for the presence or absence of ARSA using both the conventional and the novel “No ARSA” methods for validation purposes. A total of 226 unselected patients were enrolled in the study. The “No ARSA” sign was visualized in 218 fetuses (96.5%). In the remaining 8 cases (3.5%), the “No ARSA” sign was not demonstrated. In these fetuses, an ARSA was visualized by the conventional method. The new method exhibited 100% feasibility and was in complete agreement with the conventional method. Intra- and inter-observer agreement was excellent (κ = 1). The results of the study suggest that the “No ARSA” sign is an efficient and reliable screening tool for ARSA.
| Reference Key |
kassif2020journalthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Eran Kassif;Abraham Tsur;Shir Shust-Barequet;Oshrat Raviv;Anya Kushnir;Samar Abu Snenh;Reuven Achiron;Shali Mazaki-Tovi;Boaz Weisz;Yishay Salem;Tal Weissbach;Kassif, Eran;Tsur, Abraham;Shust-Barequet, Shir;Raviv, Oshrat;Kushnir, Anya;Abu Snenh, Samar;Achiron, Reuven;Mazaki-Tovi, Shali;Weisz, Boaz;Salem, Yishay;Weissbach, Tal; |
| Journal | journal of clinical medicine |
| Year | 2020 |
| DOI |
10.3390/jcm9082658
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.