Early Outcomes of Percutaneous Pulmonary Valve Implantation with Pulsta and Melody Valves: The First Report from Korea
Clicks: 270
ID: 111327
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
270 views
27 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #159 of 253 articles by views in journal of clinical medicine
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 253 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Percutaneous pulmonary valve implantation (PPVI) is used to treat pulmonary stenosis (PS) or pulmonary regurgitation (PR). We described our experience with PPVI, specifically valve-in-valve transcatheter pulmonary valve replacement using the Melody valve and novel self-expandable systems using the Pulsta valve. We reviewed data from 42 patients undergoing PPVI. Twenty-nine patients had Melody valves in mostly bioprosthetic valves, valved conduits, and homografts in the pulmonary position. Following Melody valve implantation, the peak right ventricle-to-pulmonary artery gradient decreased from 51.3 ± 11.5 to 16.7 ± 3.3 mmHg and right ventricular systolic pressure fell from 70.0 ± 16.8 to 41.3 ± 17.8 mmHg. Thirteen patients with native right ventricular outflow tract (RVOT) lesions and homograft underwent PPVI with the new self-expandable Pulsta valve—a nitinol wire stent mounted with a trileaflet porcine pericardial valve. Following Pulsta valve implantation, cardiac magnetic resonance imaging showed a decreased PR fraction and that the right ventricular end-diastolic volume index decreased from 166.1 ± 11.9 to 123.6 ± 12.4 mL/m2. There were no mortality, severe procedural morbidity, or valve-related complications. At the mean 14.2 month (4–57 months) follow-up, no patients had more than mild PR. PPVI using Melody and Pulsta valves was first shown to provide excellent early outcomes without serious adverse event in most patients with RVOT dysfunction in Korea.
| Reference Key |
kim2020journalearly
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ah Young Kim;Jo Won Jung;Se Yong Jung;Jae Il Shin;Lucy Youngmin Eun;Nam Kyun Kim;Jae Young Choi;Kim, Ah Young;Jung, Jo Won;Jung, Se Yong;Shin, Jae Il;Eun, Lucy Youngmin;Kim, Nam Kyun;Choi, Jae Young; |
| Journal | journal of clinical medicine |
| Year | 2020 |
| DOI |
10.3390/jcm9092769
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.