Field evaluation of two colorimetric coliphage detection methods.
Clicks: 273
ID: 109759
1994
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
273 views
77 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #76 of 150 articles by views in Applied and environmental microbiology
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 150 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Two new methods for coliphage detection, a colorimetric agar-based (CAB) method and a liquid colorimetric presence-absence (LCPA) method, were compared to the coliphage method proposed by the American Public Health Association (APHA; Standard Methods for the Examination of Water and Wastewater, 18th ed., American Public Health Association, Washington, D.C., 1992). Both new methods are based on the induction of beta-galactosidase in Escherichia coli and the release of the enzyme through a lytic cell infection. The released enzyme then cleaves a chromogenic substrate which produces a colored reaction product. Ninety split water samples from four different sources were tested. A total of 52 samples were positive by the CAB method, 52 were positive by the LCPA method, and 53 were positive by the APHA method. Results indicated that (i) the CAB and LCPA methods were as sensitive in coliphage detection as the APHA method, (ii) both the CAB and LCPA methods were easier to read and interpret than the APHA method, and (iii) the CAB method detected more coliphages in a positive sample than the APHA method in two of the four types of water sources. Importantly, the rapid and simple LCPA method was as reliable and sensitive as either of the two agar-based methods in coliphage detection.
| Reference Key |
ijzerman1994fieldapplied
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ijzerman, M M;Falkinham, J O;Reneau, R B;Hagedorn, C; |
| Journal | Applied and environmental microbiology |
| Year | 1994 |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org