Experimental investigation on combustion characteristics of flammable refrigerant R290/R1234yf leakage from heat pump system for electric vehicles.
Clicks: 243
ID: 108273
2020
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Steady Performance
75.3
/100
241 views
196 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
Concerning the issues regarding driving mileage reduction for electric vehicles (EVs) in cold climates, a heat pump system with low global warming potential refrigerant R290/R1234yf is employed as one of the promising solutions. Different from the widely used mobile refrigerant R134a, R290 and R1234yf are both flammable or explosive. The application of R290/R1234yf in the mobile heat pump system is hindered by unexpected refrigerant leakage with the existence of fire and explosion risk. In this study, the combustion characteristics of R290/R1234yf in a potential leakage process from an air-conditioning heat pump system for EVs were investigated. Firstly, thermodynamic behaviours of R290/R1234yf used in a typical heat pump system were analysed based on a special experimental facility designed for EVs. Then the leakage and combustion characteristics of R290/R1234yf including flame shape, temperature, radiation etc. were obtained by the experimental method under different initial temperature and mass flow rate conditions. It was found that R290/R1234yf leaked is difficult to ignite at low temperatures, while the blow-off phenomenon of the jet flame would occur at high temperature with high leakage mass flow rate. In addition, the results showed that combustion intensity would be enhanced by the leakage mass flow rate between 30 and 60°C. These results could provide guidance for fire detection and rescue system design for new energy vehicles.
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (230 words).
Try re-searching for a better abstract.
| Reference Key |
li2020experimentalroyal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Li, Kang;Wang, Jingwu;Luo, Shuxian;Wang, Zhenzhen;Zhou, Xuejin;Fang, Jun;Su, Lin;Tu, Ran; |
| Journal | Royal Society open science |
| Year | 2020 |
| DOI |
10.1098/rsos.191478
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.