Targeting and deep-penetrating delivery strategy for stented coronary artery by magnetic guidance and ultrasound stimulation.
Clicks: 293
ID: 107141
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
293 views
36 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #30 of 59 articles by views in ultrasonics sonochemistry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Stent placement is an effective treatment for atherosclerosis, but is suffered from in-stent restenosis (ISR) caused by stent mechanical damage. Conventional ISR treatment such as drug-eluting stents (DES) is challenged by the low therapeutic efficacy and severe complications, unchangeable drug dosage for individuals, and limited drug penetration in the vascular tissue. We hypothesize that magnetic targeting and deep-penetrating delivery strategy by magnetic guidance and ultrasound stimulation might be an effective approach for ISR treatment. In the present study, antiproliferative drug (paclitaxel, PTX) loaded poly (lactide-co-glycolide) (PLGA) nanoparticles (PLGA-PTX) were embedded within the shells of the magnetic nanoparticle coated microbubbles (MMB-PLGA-PTX). Once being targeted to the stent under a magnetic field, a low intensity focused ultrasound (LIFU) is applied to activate stable microbubble oscillations, thereby triggering the release of PLGA-PTX. The generated mechanical force and microstreaming facilitate the penetration of released PLGA-PTX into the thickened vascular tissue and enhance their internalization by smooth muscle cells (SMCs), thereby reducing the clearance by blood flow. In an ex vivo experiment, magnetic targeting improved the accumulation amount of MMB-PLGA-PTX by 10 folds, while the LIFU facilitated the penetration of released PLGA-PTX into the tunica media region of the porcine coronary artery, resulting in prolonged retention time at the stented vascular tissue. With the combination effects, this strategy holds great promise in the precision delivery of antiproliferative drugs to the stented vascular tissue for ISR treatment.
| Reference Key |
wang2020targetingultrasonics
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Wang, Siyu;Guo, Xixi;Ren, Lili;Wang, Bo;Hou, Lixin;Zhou, Hao;Gao, Qinchang;Gao, Yu;Wang, Lianhui; |
| Journal | ultrasonics sonochemistry |
| Year | 2020 |
| DOI |
S1350-4177(19)31813-9
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.