Modeling and correction of image pixel hysteresis in atomic force microscopy.
Clicks: 361
ID: 106553
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.2
/100
361 views
45 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #2 of 10 articles by views in ultramicroscopy
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In an atomic force microscope (AFM) system, the measurement accuracy in the scan images is determined by the displacement accuracy of piezo scanner. The hysteresis model of piezo scanner displacement is complex and difficult to correct, which is the main reason why the output displacement of the piezo scanner does not have high precision. In this study, an image pixel hysteresis model of the piezo scanner displacement in the AFM system was established. An AFM was used to scan a two-dimensional (2D) grating in the 0 ° and 90 ° directions and a polynomial fitting method was employed to obtain the image pixel hysteresis model parameters of the piezo scanner displacement in the X-direction and Y-direction. The image pixel hysteresis model was applied to correct the AFM scan image of regular octagons. The results showed that the relative measurement error in the X-direction was decreased from 12.47% to 0.52% after the correction and that in the Y-direction decreased from 28.57% to 0.35%. The image pixel hysteresis model can be applied in the post-processing software of a commercial AFM system. The model solves the hysteresis problem of the AFM system and improves the measuring accuracy of AFM in 2 degrees of freedom (2 DOF).
| Reference Key |
sun2020modelingultramicroscopy
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Sun, Baishun;Cao, Liang;Lu, Zhengcheng;Xie, Chenchen;Song, Zhengxun;Weng, Zhankun;Wang, Zuobin; |
| Journal | ultramicroscopy |
| Year | 2020 |
| DOI |
S0304-3991(19)30344-4
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org