Tripeptide Derivative-Modified Glassy Carbon Electrode: A Novel Electrochemical Sensor for Sensitive and Selective Detection of Cd Ions.

Clicks: 469
ID: 106454
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #14 of 475 articles by views in ACS omega

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 475 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A -[(Benzyloxy)carbonyl]-l-alanyl-l-prolyl-l-leucine--cyclohexylcyclohexanamine (Cbz-APL) tripeptide-coated glassy carbon electrode (GCE)-based sensor was used for sensitive and selective recognition of cadmium ions in environmental water. Detailed cyclic voltammetric and electrochemical impedance spectroscopic studies were performed to investigate the charge transfer and sensing activity of the developed electrochemical sensor. Square wave anodic stripping voltammetry (SWASV) was employed to further investigate the sensitivity, selectivity, validity, and applicability of the developed sensor. A sharp electrochemical signal of oxidized Cd at -0.84 V Ag/AgCl provides evidence for the higher sensing ability of Cbz-APL/GCE than bare GCE at -0.79 V. Moreover, on Cbz-APL/GCE, extraordinary low detection limits of 4.34 fM and linearity range of 15 nM to 0.1 pM with coefficients of correlation higher than 0.99 for Cd were achieved. Besides, the influence of inorganic and organic interferents on the targeted analyte signals was examined, and high selectivity of Cbz-APL/GCE for Cd ions was observed. Lastly, the validity and applicability of the developed electrochemical sensor for the detection of Cd ions were checked in real water samples, and 100% recovery was obtained.
Reference Key
kokab2020tripeptideacs Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Kokab, Tayyaba;Shah, Afzal;Nisar, Jan;Khan, Asad Muhammad;Khan, Sher Bahadar;Shah, Aamir Hassan;
Journal ACS omega
Year 2020
DOI
10.1021/acsomega.0c00760
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.