Tripeptide Derivative-Modified Glassy Carbon Electrode: A Novel Electrochemical Sensor for Sensitive and Selective Detection of Cd Ions.
Clicks: 469
ID: 106454
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
469 views
57 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #14 of 475 articles by views in ACS omega
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 475 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A -[(Benzyloxy)carbonyl]-l-alanyl-l-prolyl-l-leucine--cyclohexylcyclohexanamine (Cbz-APL) tripeptide-coated glassy carbon electrode (GCE)-based sensor was used for sensitive and selective recognition of cadmium ions in environmental water. Detailed cyclic voltammetric and electrochemical impedance spectroscopic studies were performed to investigate the charge transfer and sensing activity of the developed electrochemical sensor. Square wave anodic stripping voltammetry (SWASV) was employed to further investigate the sensitivity, selectivity, validity, and applicability of the developed sensor. A sharp electrochemical signal of oxidized Cd at -0.84 V Ag/AgCl provides evidence for the higher sensing ability of Cbz-APL/GCE than bare GCE at -0.79 V. Moreover, on Cbz-APL/GCE, extraordinary low detection limits of 4.34 fM and linearity range of 15 nM to 0.1 pM with coefficients of correlation higher than 0.99 for Cd were achieved. Besides, the influence of inorganic and organic interferents on the targeted analyte signals was examined, and high selectivity of Cbz-APL/GCE for Cd ions was observed. Lastly, the validity and applicability of the developed electrochemical sensor for the detection of Cd ions were checked in real water samples, and 100% recovery was obtained.
| Reference Key |
kokab2020tripeptideacs
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Kokab, Tayyaba;Shah, Afzal;Nisar, Jan;Khan, Asad Muhammad;Khan, Sher Bahadar;Shah, Aamir Hassan; |
| Journal | ACS omega |
| Year | 2020 |
| DOI |
10.1021/acsomega.0c00760
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.