Abstract
In this study, electrochemical measurements, immersion tests, and slow strain rate tensile (SSRT) tests were applied to investigate the electrochemical and stress corrosion cracking (SCC) behavior of X70 steel in simulated seawater with the interference of different alternating current (AC) densities. The results indicate that AC significantly strengthens the cathodic reaction, especially the oxygen reduction reaction. Simultaneously, hydrogen evolution reaction occurs when the limiting diffusion current density of oxygen reaches, and thus, icorr sharply increases with the increase in AC density. Additionally, when AC is imposed, the X70 steel exhibits higher SCC susceptibility in the simulated seawater, and the susceptibility increases with the increasing AC density. The SCC mechanism is controlled by both anodic dissolution (AD) and hydrogen embrittlement (HE) with the interference of AC.
Reference Key
wu2018materialselectrochemical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Wei Wu;Yue Pan;Zhiyong Liu;Cuiwei Du;Xiaogang Li
Journal Nature Materials
Year 2018
DOI 10.3390/ma11071074
URL