A novel electrogenerated chemiluminescence biosensor for histone acetyltransferases activity analysis and inhibition based on mimetic superoxide dismutase of tannic acid assembled nanoprobes.
Clicks: 440
ID: 99425
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
440 views
57 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #8 of 85 articles by views in Biosensors & bioelectronics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A simple and sensitive turn-off electrogenerated chemiluminescence (ECL) biosensor was designed for the analysis of histone acetyltransferases (HATs) activity and inhibitor evaluation based on the anti-hydrolysis ability of acetylated peptide and mimetic superoxide dismutase (SOD) features of tannic acid (TA) assembled gold nanoparticles (AuNPs) nanoprobes. In this strategy, after the acetylated reaction in the presence of HATs, the acetylated peptide on electrode was resistance to the hydrolysis of trypsin, and can absorb AuNPs@TA-Fe probe onto the electrode by the hydrophobic interaction and hydrogen bonding interaction. Thus, the ECL signal of the modified electrode in luminol solution decreased significantly owing to the mimetic SOD features of the TA assembled nanoprobe that can eliminate the reactive oxygen species. The ECL intensity changes can be utilized for sensitive HATs activities detection and inhibitor screening. The detection limit of the as-prepared ECL biosensor was 0.074 nM (S/N = 3). Moreover, the as designed ECL biosensor was also applied in MCF-7 cell lysates for HATs activity analysis and drug inhibition, which is feasible to HATs activity analysis and inhibitor screening, and presents highly promise in HAT-related clinical diagnostics.
| Reference Key |
zou2018abiosensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zou, Yan;Wang, Zonghua;Zhang, Huixin;Liu, Yang; |
| Journal | Biosensors & bioelectronics |
| Year | 2018 |
| DOI |
S0956-5663(18)30741-3
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.