Autologous internal limiting membrane transplant for recurrent idiopathic macular holes.

Clicks: 310
ID: 97388
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #4 of 7 articles by views in european journal of ophthalmology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
To report a series of recurrent idiopathic macular holes treated by means of a free autologous internal limiting membrane flap and compare visual and anatomic results to a control group undergoing further internal limiting membrane peeling and novel gas tamponade.Retrospective surgical series of 15 consecutive patients receiving autologous internal limiting membrane flap compared to 14 patients operated on for internal limiting membrane peeling enlargement. Autologous internal limiting membrane flap was created after brilliant blue G staining, internal limiting membrane lifting, perfluorocarbon bubble injection and creation of a wide internal limiting membrane free flap translocated underneath perfluorocarbon liquid, to the macular hole bed. Both groups were tamponated with 20% SF6 and positioned face down for 4 h a day for 3 days.Macular hole closed in 14/15 (93.3%) patients of the autologous internal limiting membrane group and 9/14 (64.2%) controls (p < 0.05). Visual acuity increased from 0.05 ± 0.03 to 0.23 ± 0.13 Snellen in the autologous internal limiting membrane group and from 0.05 ± 0.03 to 0.14 ± 0.10 Snellen of controls (p < 0.05 for both). Vision of the autologous internal limiting membrane group improved more than controls at 1 month (p = 0.043) and 3 months (p = 0.045). Inner segment/outer segment interruption at 3 months was smaller in the autologous internal limiting membrane group than controls, reducing from 1230 ± 288 µm at baseline to 611 ± 245 and 547 ± 204 µm at 3 months versus 1196 ± 362, 745 ± 222 and 705 ± 223 µm, respectively (p < 0.05).Autologous internal limiting membrane flap can effectively close recurrent idiopathic macular holes with a higher closure rate, smaller residual inner segment/outer segment line interruption and higher visual acuity at 3 months than previous standard of care.
Reference Key
rossi2020autologouseuropean Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Rossi, Tommaso;Trillo, Carlandrea;Ripandelli, Guido;
Journal european journal of ophthalmology
Year 2020
DOI
10.1177/1120672120906391
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.