THERMOCOAX rhodium SPND sensitivity dispersion and validation of the sensitivity calculation model

Clicks: 409
ID: 97230
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #6 of 107 articles by views in epj web of conferences

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This paper describes the neutron irradiation tests of 7 THERMOCOAX Self-Powered Neutron detectors (SPNDs) in the BR1 reactor at SCK•CEN. The SPNDs were fabricated according to the same specifications, but from different fabrication batches. The SPND signals were recorded during stepwise power-up of the reactor, proving the linearity of the SPND response within a wide thermal neutron flux range: from as low as 0.8·109 n/(cm2) to 2.6·1011 n/(cm2s). Intercomparison of the SPND signals shows a very small spread, confirming the repeatability of the THERMOCOAX fabrication processes. The overall neutron sensitivities of the seven SPNDs agreed within a 1% margin. The experimental data were analyzed in terms of prompt and various delayed responses. Prompt contributions to the signal are due to external gamma induced processes and to processes involving gamma rays emitted instantaneously upon neutron capture. The main contribution in a rhodium SPND is due to activation of the rhodium emitter and beta emission during decay of the activated rhodium and leads to a delayed response with a characteristic time of a few minutes. Activation and subsequent beta decay in other materials present in the SPND lead to additional minor delayed signal contributions. The partial SPND sensitivities due to all these processes were calculated using an MCNPX based model and were compared with experimental sensitivities based on the recorded data. The results were in fair agreement; for the overall SPND neutron sensitivity an agreement within a 1% margin was achieved.
Reference Key
l2020thermocoaxepj Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors L., Vermeeren;W., Leysen;L., Pichon;V., Salou;G., Helleux;
Journal epj web of conferences
Year 2020
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.