Velocity-space sensitivity of the compact neutron emission spectrometers at EAST.
Clicks: 239
ID: 97189
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
239 views
34 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #22 of 39 articles by views in The Review of scientific instruments
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Several compact neutron spectrometers are now installed at EAST (Experimental Advanced Superconducting Tokamak) to obtain information on fuel ions produced in the core of the plasma. In this paper, a stilbene crystal neutron spectrometer and an EJ301 liquid scintillator neutron spectrometer with n-γ discrimination capability will be discussed. Both spectrometers have a horizontal line of sight, while at different positions. In the last few experiment campaigns at EAST, they all proved to be reliable diagnostics for auxiliary heated D-D plasmas. Taking the response function simulated by dedicated Geant4 models into consideration, the velocity-space sensitivities given by the instrument-specific weight function of the beam-thermal part of neutron energy spectra in D-D plasmas are derived for both spectrometers with the Genesis code. This method makes it possible to directly relate the contribution of different deuteron velocity space regions to events in each channel of the neutron spectrum measured by the two instruments: http://rsi-htpd.peerx-press.org/.
| Reference Key |
zhang2018velocityspacethe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhang, Y M;Ge, L J;Sun, J Q;Hu, Z M;Nocente, M;Gorini, G;Tardocchi, M;Zhong, G Q;Hu, L Q;Li, X Q;Fan, T S; |
| Journal | The Review of scientific instruments |
| Year | 2018 |
| DOI |
10.1063/1.5039393
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.