The large helical device vertical neutron camera operating in the MHz counting rate range.
Clicks: 335
ID: 97186
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
75.8
/100
335 views
232 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #8 of 39 articles by views in The Review of scientific instruments
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In the currently performed neutral beam (NB) -heated deuterium plasma experiments, neutrons are mainly produced by a beam-plasma reaction. Therefore, time-resolved measurement of the neutron emission profile can enhance the understanding of the classical and/or anomalous transport of beam ions. To measure radial neutron emission profiles as a function of time, the vertical neutron camera (VNC) capable of operation with a counting rate in the MHz range was newly installed on the Large Helical Device (LHD). This is the world's first neutron camera for stellarator/heliotron devices. The VNC consists of a multichannel collimator, eleven fast-neutron detectors, and the digital-signal-processing-based data acquisition system (DAQ). The multichannel collimator having little cross talk was made from hematite-doped heavy concrete, which has a high shielding performance against both neutrons and gamma-rays. A stilbene crystal coupled with a photomultiplier having high-gain-stability in the high-count rate regime was utilized as a fast-neutron scintillation detector because it has a high neutron-gamma discrimination capability at high count rates. The DAQ system equipped with a field programmable logic controller was developed to obtain the waveform acquired with a 1 GHz sampling rate and the shaping parameter of each pulse simultaneously at up to 10 cps (counts per second). Neutron emission profiles were successfully obtained in the first deuterium campaign of LHD in 2017. The neutron emission profile was measured in tangentially co-injected NB-heated plasma with different magnetic axes (). The neutron counts became larger in the inward-shifted configuration, which was consistent with the total neutron rate measured by the neutron flux monitor. The radial peak position of the line-integrated neutron profile which changed according to showed that the VNC worked successfully as designed. The VNC demonstrated the expected performance conducive to extending energetic-particle physics studies in LHD.
| Reference Key |
ogawa2018thethe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ogawa, K;Isobe, M;Nishitani, T;Kobuchi, T; |