DISCRIMINATION METHOD FOR GAMMA RAY DOSES IN NEUTRON FIELDS USING AN IONIZATION CHAMBER WITH ATTENUATION FILTERS.
Clicks: 350
ID: 97184
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
350 views
37 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #4 of 44 articles by views in Radiation protection dosimetry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Neutron fields produced by an accelerator-driven neutron source are generally mixed radiation fields that consist of fast neutrons and gamma rays. To estimate the biological effects of fast neutrons precisely, the gamma ray dose contamination must be evaluated in neutron fields. In this work, we developed a discrimination technique for absorbed doses (60Co gamma-ray equivalent) of fast neutrons and gamma rays using an ionization chamber. The filter thickness dependences of the absorbed doses of fast neutrons and gamma rays are different for a given filter material. Thus, the absorbed doses of each type of radiation were distinguished by fitting the dose attenuation curve, which was measured with an ionization chamber and attenuation filters, with a two-component exponential function. The absorbed dose of fast neutrons and gamma rays with no attenuation filter was evaluated from the y-intercept of the fitting function. This technique was demonstrated in two neutron fields produced by 4 MeV proton and deuteron bombardment of a 9Be target. The thicknesses of the polyethylene attenuation filters were 0-350 mm. The dose attenuation coefficients of fast neutrons obtained by the two-component exponential fitting function for the 9Be(p,n)9 and 9Be(d,n) reactions showed differences of 1.5 and 1.7%, respectively, from the reference measurements using a CR-39 plastic nuclear track detector. The absorbed dose contributions of gamma rays in neutrons fields of the 9Be(p,n)9B and 9Be(d,n) reactions were evaluated as 30.2 ± 3.24% and 20.4 ± 5.16%, respectively, without polyethylene filters.
| Reference Key |
ogawara2019discriminationradiation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ogawara, R;Suda, M;Hagihara, T;Kodaira, S;Hamano, T; |
| Journal | Radiation protection dosimetry |
| Year | 2019 |
| DOI |
10.1093/rpd/ncz002
|