Design optimization of a fast-neutron detector with scintillating fibers for triton burnup experiments at fusion experimental devices.
Clicks: 245
ID: 97183
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
245 views
29 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #19 of 39 articles by views in The Review of scientific instruments
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Time-resolved triton burnup studies have been carried out to estimate the behavior of alpha particles in DD fusion experimental devices. In those studies, 14 MeV neutrons emitted through DT reactions in DD plasmas should be measured selectively in the backgrounds of DD neutrons and gamma rays. For this purpose, a scintillating-fiber (Sci-Fi) based fast-neutron detector has been adapted because of its advantages such as fast response, design flexibility in detection efficiency by changing the number of Sci-Fi, and discrimination property against 2.4 MeV neutrons produced through DD reactions and gamma rays. However, its length had conventionally been set to around 10 cm without an optimization study of its design parameters to meet the requirements as 14 MeV neutron detector. In the present study, we tested three types of Sci-Fi detectors with three different lengths and compared with the simulated results of energy deposition, through which we tried to understand the phenomena in the detection process of fast neutrons. From the results, it has been shown that, due to the self-shielding of neutrons by Sci-Fi and the attenuation of scintillation photons during the transmission process to the photomultiplier tube, the optimal length of Sci-Fi is concluded to be about 6 cm.
| Reference Key |
takada2019designthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Takada, E;Amitani, T;Fujisaki, A;Ogawa, K;Nishitani, T;Isobe, M;Jo, J;Matsuyama, S;Miwa, M;Murata, I; |
| Journal | The Review of scientific instruments |
| Year | 2019 |
| DOI |
10.1063/1.5074131
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org