Optimization of MAXED input parameters with applications to the unfolding of neutron diagnostics data from the Joint European Torus.
Clicks: 257
ID: 97180
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
257 views
37 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #16 of 39 articles by views in The Review of scientific instruments
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Organic NE213 liquid scintillator neutron detectors are commonly used at accelerator facilities for neutron beam diagnostics. In recent years, they have also been installed at nuclear fusion facilities to measure the neutron energy spectra from Deuterium (D) and Deuterium-Tritium plasmas, e.g., at the ASDEX Upgrade (Garching, Germany) and at the Joint European Torus (JET, Culham, UK). The NE213 equivalent scintillating material (now BC501A) of the detector is sensitive to neutron and gamma radiation, so pulse discrimination techniques are applied in order to obtain the measured neutron pulse height spectrum (PHS). If the neutron detector is stable, controlled, and well-characterized (i.e., its response function to incoming neutrons of known energy is determined with high accuracy), it can be used as a neutron spectrometer. The measured PHS can then be analyzed using standard techniques such as unfolding to determine the incoming neutron energy spectrum. This article focuses on the unfolding of neutron data measured in D plasma experiments at JET by a compact broadband neutron spectrometer using the maximum entropy unfolding code MAXED. A general method for optimizing MAXED input parameters is described and applied to the measured PHS to diagnose the effects of the auxiliary heating of JET D plasma on the neutron energy spectra.
| Reference Key |
giacomelli2019optimizationthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Giacomelli, L;Reginatto, M;, ; |
| Journal | The Review of scientific instruments |
| Year | 2019 |
| DOI |
10.1063/1.5097784
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org