Neutron detection performance of gallium nitride based semiconductors.
Clicks: 223
ID: 97179
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
223 views
40 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1,032 of 1,628 articles by views in Scientific reports
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,628 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Neutron detection is crucial for particle physics experiments, nuclear power, space and international security. Solid state neutron detectors are of great interest due to their superior mechanical robustness, smaller size and lower voltage operation compared to gas detectors. Gallium nitride (GaN), a mature wide bandgap optoelectronic and electronic semiconductor, is attracting research interest for neutron detection due to its radiation hardness and thermal stability. This work investigated thermal neutron scintillation detectors composed of GaN thin films with and without conversion layers or rare-earth doping. Intrinsic GaN-based neutron scintillators are demonstrated via the intrinsic N(n, p) reaction, which has a small thermal neutron cross-section at low neutron energies, but is comparable to other reactions at high neutron energies (>1 MeV). Gamma discrimination is shown to be possible with pulse-height in intrinsic GaN-based scintillation detectors. Additionally, GaN-based scintillation detector with a LiF neutron conversion layer and Gd-doped GaN detector are compared with intrinsic GaN detectors. These results indicate GaN scintillator is a suitable candidate neutron detector in high-flux applications.
| Reference Key |
zhou2019neutronscientific
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhou, Chuanle;Melton, Andrew G;Burgett, Eric;Hertel, Nolan;Ferguson, Ian T; |
| Journal | Scientific reports |
| Year | 2019 |
| DOI |
10.1038/s41598-019-53664-7
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.