DEMONSTRATION OF THE POTENTIAL AND DIFFICULTIES OF COMBINED TL AND OSL MEASUREMENTS OF TLD-600 AND TLD-700 FOR THE DETERMINATION OF THE DOSE COMPONENTS IN COMPLEX NEUTRON-GAMMA RADIATION FIELDS.
Clicks: 218
ID: 97178
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
218 views
20 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #16 of 43 articles by views in Radiation protection dosimetry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The results reported herein demonstrate the potential application of combined optically stimulated luminescence/thermoluminescent (OSL/TL) measurements in neutron-gamma discrimination dosimetry. The advantages of OSL/TL are two-fold: (i) The OSL and TL readout can be carried out on the same sample and (ii) the greater efficiency of OSL to high ionization density radiation due to F 2 and F3 excitation. The gamma/electron calibration coefficients for LiF:Mg, Ti (TLD-600 and TLD-700) were measured using a 90Sr/90Y source calibrated at the SARAF-SSDL nuclear facility. The estimation of the neutron calibration coefficients was carried out by irradiation with broad-spectrum beam of fast neutrons with median energy 5 MeV at the Radiological Research Accelerator Facility (RARAF) of Columbia University. Naturally cooled samples of TLD-600 and TLD-700 were dosed to levels of 29.8 Gy neutrons and 6.1 Gy gammas in air and KERMA calculations employed to transfer the levels of dose to6,7LiF. A figure of merit for fast-neutron/gamma ray discrimination was determined at 10.6 for TLD-700 in the current measurements. The use of combined TLD-600/TLD-700 allowed, as well, the determination of a considerable and somewhat unexpected thermal neutron component of 116 Gy in TLD-600.
| Reference Key |
oster2020demonstrationradiation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Oster, L;Eliyahu, I;Horowitz, Y S;Reshes, G;Shapiro, A;Garty, G; |
| Journal | Radiation protection dosimetry |
| Year | 2020 |
| DOI |
ncz297
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.