Intra- and inter-observer reproducibility of volume measurement of knee cartilage segmented from the OAI MR image set using a novel semi-automated segmentation method.

Clicks: 503
ID: 96628
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #3 of 28 articles by views in osteoarthritis and cartilage

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
We developed a semi-automated method based on a graph-cuts algorithm for segmentation and volumetric measurements of the cartilage from high-resolution knee magnetic resonance (MR) images from the Osteoarthritis Initiative (OAI) database and assessed the intra- and inter-observer reproducibility of measurements obtained via this method.MR image sets from 20 subjects of varying Kellgren-Lawrence (KL) grades (from 0 to IV) on fixed flexion knee radiographs were selected from the baseline double-echo and steady-state (DESS) knee MR images in the OAI database (0.B.1 Imaging Data set). Two trained radiologists independently performed the segmentation of knee cartilage twice using the semi-automated method. The volumes of segmented cartilage were computed and compared. The intra- and inter-observer reproducibility were determined by means of the coefficient of variation (CV%) of repeated cartilage segmented volume measurements. The subjects were also divided into the low- (0, I or II) and high-KL (III or IV) groups. The differences in cartilage volume measurements and CV% within and between the observers were tested with t tests.The mean (+/-SD) intra-observer CV% for the 20 cases was 1.29 (+/-1.05)% for observer 1 and 1.67 (+/-1.14)% for observer 2, while the mean (+/-SD) inter-observer CV% was 1.31 (+/-1.26)% for session 1 and 1.79 (+/-1.72)% for session 2. There was no significant difference between the two intra-observer CV%'s (P=0.272) and between the two inter-observer CV%'s (P=0.353). The mean intra-observer CV% of the low-KL group was significantly smaller than that for the high-KL group for observer 1 (0.83 vs 1.86%: P=0.025). The segmentation processing times used by the two observers were significantly different (observer 1 vs 2): (mean 49+/-12 vs 33+/-6min) for session 1 and (49+/-8 vs 32+/-8min) for session 2.The semi-automated graph-cuts method allowed us to segment and measure cartilage from high-resolution 3T MR images of the knee with high intra- and inter-observer reproducibility in subjects with varying severity of OA.
Reference Key
bae2009intraosteoarthritis Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal osteoarthritis and cartilage
Year 2009
DOI
10.1016/j.joca.2009.06.003
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.