Automated quantification of carotid artery stenosis on contrast-enhanced MRA data using a deformable vascular tube model.

Clicks: 455
ID: 96625
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #2 of 8 articles by views in the international journal of cardiovascular imaging

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The purpose of this study was to develop and validate a method for automated segmentation of the carotid artery lumen from volumetric MR Angiographic (MRA) images using a deformable tubular 3D Non-Uniform Rational B-Splines (NURBS) model. A flexible 3D tubular NURBS model was designed to delineate the carotid arterial lumen. User interaction was allowed to guide the model by placement of forbidden areas. Contrast-enhanced MRA (CE-MRA) from 21 patients with carotid atherosclerotic disease were included in this study. The validation was performed against expert drawn contours on multi-planar reformatted image slices perpendicular to the artery. Excellent linear correlations were found on cross-sectional area measurement (r = 0.98, P < 0.05) and on luminal diameter (r = 0.98, P < 0.05). Strong match in terms of the Dice similarity indices were achieved: 0.95 ± 0.02 (common carotid artery), 0.90 ± 0.07 (internal carotid artery), 0.87 ± 0.07 (external carotid artery), 0.88 ± 0.09 (carotid bifurcation) and 0.75 ± 0.20 (stenosed segments). Slight overestimation of stenosis grading by the automated method was observed. The mean differences was 7.20% (SD = 21.00%) and 5.2% (SD = 21.96%) when validated against two observers. Reproducibility in stenosis grade calculation by the automated method was high; the mean difference between two repeated analyses was 1.9 ± 7.3%. In conclusion, the automated method shows high potential for clinical application in the analysis of CE-MRA of carotid arteries.
Reference Key
suinesiaputra2012automatedthe Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal the international journal of cardiovascular imaging
Year 2012
DOI
10.1007/s10554-011-9988-x
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.