Evaluation of Outcome Variability Associated With Lateral Wall, Mid-scalar, and Perimodiolar Electrode Arrays When Controlling for Preoperative Patient Characteristics.
Clicks: 337
ID: 96451
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
74.3
/100
337 views
207 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #7 of 11 articles by views in otology & neurotology : official publication of the american otological society, american neurotology society [and] european academy of otology and neurotology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Determine the impact of electrode array selection on audiometric performance when controlling for baseline patient characteristics.Retrospective evaluation of a prospective cochlear implant (CI) database (January 1, 2012-May 31, 2017).Tertiary Care University Hospital.Three hundred twenty-eight adult CI recipients.Hearing outcomes were measured through unaided/aided pure tone thresholds and speech recognition testing before and after cochlear implantation. All reported postoperative results were performed at least 6 months after CI activation. All device manufacturers were represented.Of the 328 patients, 234 received lateral wall (LW) arrays, 46 received perimodiolar (PM) arrays, and 48 received mid-scalar (MS) arrays. Patients receiving PM arrays had significantly poorer preoperative earphone and aided PTAs and SRTs, and aided Consonant-Nucleus-Consonant(CNC) word and AzBio +10 SNR scores compared with patients receiving LW arrays (all p ≤ 0.04), and poorer PTAs and AzBio +10 SNR scores compared with MS recipients (all p ≤ 0.02). No preoperative audiological variables were found to significantly differ between MS and LW patients. After controlling for preoperative residual hearing and speech recognition ability in a hierarchical multiple regression analysis, no statistically significant difference in audiological outcomes was detected (CNC words, AzBio quiet, or AzBio +10 SNR) among the three electrode array types (all p > 0.05).While previous studies have demonstrated superior postoperative speech recognition scores in LW electrode array recipients, these differences lose significance when controlling for baseline hearing and speech recognition ability. These data demonstrate the proclivity for implanting individuals with greater residual hearing with LW electrodes and its impact on postoperative results.
| Reference Key |
fabie2018evaluationotology
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Fabie, Joshua E;Keller, Robert G;Hatch, Jonathan L;Holcomb, Meredith A;Camposeo, Elizabeth L;Lambert, Paul R;Meyer, Ted A;McRackan, Theodore R; |
| Journal | otology & neurotology : official publication of the american otological society, american neurotology society [and] european academy of otology and neurotology |
| Year | 2018 |
| DOI |
10.1097/MAO.0000000000001951
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.