Instantaneous frequency based index to characterize respiratory crackles.
Clicks: 191
ID: 96446
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
191 views
16 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #41 of 87 articles by views in Computers in biology and medicine
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Crackle is a lung sound widely employed by health staff to identify respiratory diseases. The two-cycle duration (2CD) is a quantitative index pointed out by the American Thoracic Society and the European Respiratory Society to classify respiratory crackles as fine or coarse. However, this index, measured in the time domain, is highly affected by noise and filters of recording systems. Such factors hamper the analysis of data reported by different research groups. This work proposes a new index based on the instantaneous frequency of crackles estimated by means of discrete-time pseudo Wigner-Ville distribution.Comparisons between 2CD and the proposed index were carried out for simulated and actual crackles. Normal breathing sounds were added to simulated crackles; the resulting signals were then applied to a band-pass filter that mimics those belonging to lung sound acquisition systems. Thus, the impact of noise and filtering on these two indices was assessed for simulated crackles. Kruskal-Wallis and Dunn's tests as well as Gaussian mixture model (GMM) were applied to the two indices measured from 382 actual crackles belonging to open databases.The proposed index is much less susceptible to waveform distortions due to noise and filtering when compared to the 2CD. Thus, the statistical analyses allow the identification of two classes of crackles from actual databases; the same does not occur when using 2CD.The new proposed index has the potential to contribute for a better characterization of crackles generated by different respiratory diseases, assisting their diagnosis during clinical exams.
| Reference Key |
speranza2018instantaneouscomputers
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Speranza, Carlos G;Moraes, Raimes; |
| Journal | Computers in biology and medicine |
| Year | 2018 |
| DOI |
S0010-4825(18)30263-4
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.