Optimization and validation of a SPE-HPLC-PDA-fluorescence method for the simultaneous determination of drugs used in combined cardiovascular therapy in human plasma.
Clicks: 244
ID: 96197
2009
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
7.5
/100
25 views
25 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
This paper reports the chemometrical optimization and the validation of a quantitative high performance liquid chromatography-photodiode array-fluorescence (HPLC-PDA-Fluo) method for the simultaneous analysis, in human plasma, of drugs usually combined in cardiovascular therapy. Separation of chlorthalidone (CLTD), valsartan (VAL), valsartan-M1 (VAL-M1), fluvastatin (FLUV) and the internal standard (IS) candesartan cilexetil was performed on a dC18 Atlantis column (100 mm x 3.9 mm, 3 microm) using a gradient with a run time of 15 min. The mobile phase consisted of a mixture of acetonitrile and water containing 0.01% of formic acid and 10 mM of ammonium formate at pH 4.1. UV and fluorimetric (valsartan, its metabolite and fluvastatin) detectors were used. The sample preparation consisted of protein precipitation using acetonitrile suited to a solid-phase extraction (SPE) on a Strata-X cartridge for sample clean-up. Method validation was developed following the recommendations for bioanalytical method validation of International Conference on Harmonisation (ICH) and Food and Drug Administration (FDA) organizations. The method showed good linearity (31-3000 microg/l for chlorthalidone, 20-1000 microg/l for valsartan-M1, 10-5000 microg/l for valsartan and 14-1000 microg/l for fluvastatin), precision and accuracy. Recoveries were in the range of 78-91%. This method allowed the determination of these drugs in human plasma samples obtained from patients under cardiovascular treatment.
| Reference Key |
gonzalez2009optimizationjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Gonzalez, Oskar;Iriarte, Gorka;Ferreirós, Nerea;Maguregui, Miren Itxaso;Alonso, Rosa Maria;Jiménez, Rosa Maria; |
| Journal | Journal of pharmaceutical and biomedical analysis |
| Year | 2009 |
| DOI |
10.1016/j.jpba.2008.10.037
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.