Numerical simulation of blood flow inside an artery under applying constant heat flux using Newtonian and non-Newtonian approaches for biomedical engineering.

Clicks: 402
ID: 94638
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #8 of 70 articles by views in computer methods and programs in biomedicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
In this paper, different behaviors of blood flow are simulated inside the artery under applying a constant heat flux on the artery boundary walls.To simulate the blood flow, the Sisko model is employed. Then, the temperature and Nusselt number of blood flow are reported for different Sisko parameters. Afterward, the effects of different artery radiuses are studied on the Nusselt number.Medical treatment by replenishes fluid and electrolytes in the body vessels can change blood flow properties from non-Newtonian behavior to Newtonian behavior, which increases heat transfer in blood flow and causes to reduce blood flow temperature. In this research, the maximum temperature of Newtonian blood fluid flow is reported as much as 310.0045 K, whereas; maximum flow temperature in non-Newtonian blood fluid is 310.007 K. These results emphasize the effects of the type of Newtonian and non-Newtonian fluid model on the thermal behavior of blood inside body vessels. Since medical science does not permit body temperature to be changed from the normal condition, this small variation can be noticeable and sensible on the health. Hence, medical scientific research centers and institutes of vaccine and serum have to be careful in the mechanical design of drugs for blood fluid.The results of this research show the application of mechanical engineering for some of the medical concerns in designing the drugs which are effective on the behavior of human body blood.
Reference Key
foong2020numericalcomputer Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Foong, Loke Kok;Shirani, Nima;Toghraie, Davood;Zarringhalam, Majid;Afrand, Masoud;