Dynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback.
Clicks: 379
ID: 94337
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
379 views
33 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #4 of 6 articles by views in journal of biomedical physics & engineering
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy.This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic multi-leaf collimators.All slices which contained tumor were contoured in the 4D-CT images for 10 patients. For modelling of respiratory motion, the end-exhale phase of these images has been considered as the reference and they were analyzed using neuro-fuzzy method to predict the magnitude of displacement of the lung tumor. Then, the predicted data were used to determine the leaf motion in MLC. Finally, the trained algorithm was figured out using Shaper software to show how MLCs could track the moving tumor and then imported on the Varian Linac equipped with EPID.The root mean square error (RMSE) was used as a statistical criterion in order to investigate the accuracy of neuro-fuzzy performance in lung tumor prediction. The results showed that RMSE did not have a considerable variation. Also, there was a good agreement between the images obtained by EPID and Shaper for a respiratory cycle.The approach used in this study can track the moving tumor with MLC based on the 4D modelling, so it can improve treatment accuracy, dose conformity and sparing of healthy tissues because of low error in margins that can be ignored. Therefore, this method can work more accurately as compared with the gating and invasive approaches using markers.
| Reference Key |
n2019dynamicjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | N, Rostampour;K, Jabbari;Sh, Nabavi;M, Mohammadi;M, Esmaeili; |
| Journal | journal of biomedical physics & engineering |
| Year | 2019 |
| DOI |
10.31661/jbpe.v0i0.769
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.