Asymmetrical interval type-2 fuzzy logic control based MPPT tuning for PV system under partial shading condition.

คลิก: 279
รหัส: 94293
2020
คุณภาพบทความและตัวชี้วัดประสิทธิภาพ
คุณภาพโดยรวม
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
การประเมินคุณภาพโดย AI
ยังไม่ได้วิเคราะห์
Readership in this journal
Emerging

Ranked #24 of 43 articles by views in ISA transactions

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
บทคัดย่อ
The conventional maximum power point tracking (MPPT) algorithm shows best performance under uniform insolation but when photovoltaic (PV) array is partially irradiated, the Power vs Voltage (P-V) plot consists of multiple local maxima power point (LMPP) and one global maxima power point (GMPP). The conventional MPPT algorithm may track local peak and fluctuate around it, resulting in lower power tracking. To eradicate this drawback of conventional algorithm, the solar PV system requires the synthesis of modified controller which is able to discriminate between local and global peak point. Along with implementing modified MPPT controller, to minimise the adverse effect of partial shading on PV system, different PV array arrangements like series-parallel (SP), honey comb (HC), total cross tied (TCT) etc. may be used. Author(s) in the present study, has proposed asymmetrical interval type-2 fuzzy logic control (IT-2 AFLC) based MPP algorithm for tracking global peak in partial shading condition (PSC) with different PV array arrangements. The presented algorithm has been compared with other approaches viz. perturb & observe (P&O) and type-1(T-1) FLC for GMPP tracking, fill factor, shading losses, mismatch loss and efficiency to establish its superiority. For evaluating the efficiency of different algorithms, the EN50530 MPPT efficiency test has been performed under dynamic condition. The proposed algorithm has been developed under MATLAB/Simulink environment.
คีย์อ้างอิง
verma2020asymmetricalisa ใช้คีย์นี้เพื่ออ้างอิงอัตโนมัติในต้นฉบับขณะใช้งาน SciMatic Manuscript Manager หรือ Thesis Manager
ผู้เขียน Verma, Pallavi;Garg, Rachana;Mahajan, Priya;
วารสาร ISA transactions
ปี 2020
DOI
S0019-0578(20)30002-1
URL
คำสำคัญ

การอ้างอิง

ไม่พบการอ้างอิง หากต้องการเพิ่มการอ้างอิง กรุณาติดต่อผู้ดูแลระบบที่ info@scimatic.org

ยังไม่มีความคิดเห็น เป็นคนแรกที่แสดงความคิดเห็นเกี่ยวกับบทความนี้