Identifying the Sources of Error When Using 3-Dimensional Printed Head Models with Surgical Navigation.
Clicks: 201
ID: 93874
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
201 views
13 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #54 of 82 articles by views in world neurosurgery
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The evaluation of sources of error when preparing, printing, and using 3-dimensional (3D) printed head models for training purposes.Two 3D printed models were designed and fabricated using actual patient imaging data with reference marker points embedded artificially within these models that were then registered to a surgical navigation system using 3 different methods. The first method uses a conventional manual registration, using the actual patient's imaging data. The second method is done by directly scanning the created model using intraoperative computed tomography followed by registering the model to a new imaging dataset manually. The third is similar to the second method of scanning the model but eventually uses an automatic registration technique. The errors for each experiment were then calculated based on the distance of the surgical navigation probe from the respective positions of the embedded marker points.Errors were found in the preparation and printing techniques, largely depending on the orientation of the printed segment and postprocessing, but these were relatively small. Larger errors were noted based on a couple of variables: if the models were registered using the original patient imaging data as opposed to using the imaging data from directly scanning the model (1.28 mm vs. 1.082 mm), and the accuracy was best using the automated registration techniques (0.74 mm).Spatial accuracy errors occur consistently in every 3D fabricated model. These errors are derived from the fabrication process, the image registration process, and the surgical process of registration.
| Reference Key |
mehbodniya2019identifyingworld
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Mehbodniya, Amirhossein;Moghavvemi, Mahmoud;Narayanan, Vairavan;Muthusamy, Kalai A;Hamdi, Mohammad;Waran, Vicknes; |
| Journal | world neurosurgery |
| Year | 2019 |
| DOI |
S1878-8750(19)32698-1
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.