Trace-Level Persistent Organic Pollutant Analysis with Gas-Chromatography Orbitrap Mass Spectrometry-Enhanced Performance by Complementary Acquisition and Processing of Time-Domain Data.
Clicks: 303
ID: 92834
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
303 views
42 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #7 of 9 articles by views in journal of the american society for mass spectrometry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The range of commercial techniques for high-resolution gas-chromatography-mass spectrometry (GC-MS) has been recently extended with the introduction of GC Orbitrap Fourier transform mass spectrometry (FTMS). We report on progress with quantitation performance in the analysis of persistent organic pollutants (POP), by averaging of time-domain signals (), from a number of GC-FTMS experiment replicates. Compared to a standard GC-FTMS measurement (a single GC-FTMS experiment replicate, mass spectra representation in reduced profile mode), for the 10 GC-FTMS technical replicates of ultratrace POP analysis, sensitivity improvement of up to 1 order of magnitude is demonstrated. The accumulation method was implemented with an external high-performance data acquisition system and dedicated data processing software to acquire the time-domain data for each GC-FTMS replicate and to average the acquired GC-FTMS data sets. Concomitantly, the increased flexibility in ion signal detection allowed the attainment of ultrahigh-mass resolution (UHR), approaching = 700 000 at = 200.
| Reference Key |
nagornov2020traceleveljournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Nagornov, Konstantin O;Zennegg, Markus;Kozhinov, Anton N;Tsybin, Yury O;Bleiner, Davide; |
| Journal | journal of the american society for mass spectrometry |
| Year | 2020 |