Design of a Mechatronics Model of Urinary Bladder and Realization and Evaluation of Its Prototype.
Clicks: 765
ID: 92398
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
75.6
/100
765 views
556 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #1 of 10 articles by views in applied bionics and biomechanics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Annually, there are many bladder cancer patients undergoing radical cystectomy (RC) with urinary diversion worldwide. Until 2019, intestinal cystoplasty is still the gold standard for bladder replacement, but this therapy is always associated with severe complications. An ideal bladder substitute without using intestinal tissue remains a challenge today. In this work, an artificial mechatronics bladder (AMB) as a brand new bladder replacement approach is developed. We studied the main physiological function characteristics of a natural urinary bladder from teaching books and relevant papers. According to these characteristics, we completed an overall design of AMB and made a prototype in lab. The prototype successfully realized the functions of a natural bladder in vitro. It can expand to store urine in real time when urine is flowing into it. It can send a urination alarm when it is fully filled and can void urine automatically after receiving remote control signals. According to relevant papers and our test experience, if the prototype could be smaller and lighter and manufactured with good biocompatibility materials such as PTFE, we think it is possible for AMB to be implanted in an animal's body, and we deduce AMB could realize the functions of a natural urinary bladder in vivo. After thorough validation from animal testing, we hope AMB can be a good clinical option for bladder removal patients in the future.
| Reference Key |
zhuo2019designapplied
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhuo, Zhao;Dan, He;Gensong, Li;Ping, Shi;Xining, Pang; |