The comparison between force volume and peakforce quantitative nanomechanical mode of atomic force microscope in detecting cell's mechanical properties.

Clicks: 405
ID: 92265
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #6 of 15 articles by views in Microscopy research and technique

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Atomic force microscope (AFM) has been widely used in the biological field owing to its high sensitivity (subnanonewton), high spatial resolution (nanometer), and adaptability to physiological environments. Nowadays, force volume (FV) and peakforce quantitative nanomechanical (QNM) are two distinct modes of AFM used in biomechanical research. However, numerous studies have revealed an extremely confusing phenomenon that FV mode has a significant difference with QNM in determining the mechanical properties of the same samples. In this article, for the case of human benign prostatic hyperplasia cells (BPH) and two cancerous prostate cells with different grades of malignancy (PC3 and DU145), the differences were compared between FV and QNM modes in detecting mechanical properties. The results show measured Young's modulus of the same cells in FV mode was much lower than that obtained by QNM mode. Combining experimental results with working principles of two modes, it is indicated that surface adhesion is highly suspected to be a critical factor resulting in the measurement difference between two modes. To further confirm this conjecture, various weight ratios of polydimethylsiloxane (PDMS) were assessed by two modes, respectively. The results show that the difference of Young's modulus measured by two modes increases with the surface adhesion of PDMS, confirming that adhesion is one of the significant elements that lead to the measurement difference between FV and QNM modes.
Reference Key
yang2019themicroscopy Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Yang, Yang;Xiao, Xiaoxiao;Peng, Yan;Yang, Chen;Wu, Siqi;Liu, Yuanyuan;Yue, Tao;Pu, Huayan;Liu, Na;Jiang, Haowen;
Journal Microscopy research and technique
Year 2019
DOI
10.1002/jemt.23351
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.